+49 (0) 61 02 / 78 90 - 0 info@dsf-gmbh.de

InSight Compact flame scanner

Description:

The Fireye InSight 95 is a versatile compact flame scanner with many worldwide approvals. The InSight 95 scanners provide advanced discrimination capabilities, integrated flame detection, gain, safety check and flame relay in one housing. No external evaluation device (flame amplifier) is required to communicate with the higher-level control system. The flame scanner measures the amplitude of the modulations that occur in the target flame (flame “flicker”).

Fiber optic versions are optionally available for difficult visibility conditions.

The following Insight I models are discontinued as of 02 May 2020. For more details, please refer to the manufacturer announcement

Existing PartRecommended Replacement Part
95UVS1-1 (all versions including E's)95UVS4-1WINC
95UVS1-1CG (all versions including E's)95UVS4-1WINC with associated cable 59-497-XXX series
95IRS1-1 (all versions including E's)95IRS4-1WINC
95IRS1-1CG (all versions including E's)95IRS4-1WINC with associated cable 59-497-XXX series
95UVS2-1 (all versions including E's) 95UVS4-1WINC
95UVS2-1CG (all versions including E's)95UVS4-1WINC with associated cable 59-497-XXX series
95IRS2-1 (all versions including E's)95IRS4-1WINC
95IRS2-1CG (all versions including E's)95IRS4-1WINC with associated cable 59-497-XXX series
95UVS1-1CEX (all versions including E's)95UVS4-1CEX
95IRS1-1CEX (all versions including E's)95IRS4-1CEX

If necessary, please contact us before replacing a device.

FeaturesStandard Models (S1) Expanded Models (S2)
95IRS1 95UVS1 95DSS1 95IRS2 95UVS2 95DSS2
Infrared Sensor XXXX
Ultraviolet Sensor XXXX
Flame RelayXXXXXX
Fault RelayXXXXXX
4 – 20 mA Analog Output XXXXXX
Modulation Frequency Selection 333212121
Memory Files222444
CommunicationXXX
Auto Tune XXX
Pre-EditXXX
SIL2XXXXXX
EEx nA IIC T6 (Zone 2)
Class 1, Group A, B, C, & D
Class 2 , Group F&G
XXX
EEx d IIC T6 XXX

For more details, please refer to the data sheet

InSight 95IR
  • Infrared sensor
  • With LED display
  • Self-monitoring
  • Approved for continuous operation

more…

InSight 95DS
  • Dual sensor
  • With LED display
  • Self-monitoring
  • approved for continuous operation

more…

InSight 95UV
  • Ultraviolet sensor
  • With LED display
  • Self-monitoring
  • Approved for continuous operation

more…

InSight CEX
  • Ex-version
  • With LED display
  • Self-monitoring
  • Approved for continuous operation

more…

InSight 95IR

Technical data
Flame relay (normally open contact). IR- Sensor, microprocessor based semiconductor sensor, supply voltage 24V DC, process connection 1″ BSP or NPT, purge air connection 3/8″, ambient temperature range -40°C to +65°C (self-monitoring up to 80°C), NEMA 4X, IP66 housing, 3 (S1), or 21 (S2) basic modulation frequencies, adjustable gain and ON/OFF thresholds, 4-20 mA output signal, error relay, two (S1), or four (S2) selectable parameter sets, LED display and four push buttons, quick disconnect, learning mode with the possibility of manual readjustment (S2). Approved for continuous operation.

95IRS1E-1
Infrared sensor for wavelengths from 700 to 1700 nm, suitable for coal and oil firing
2 switchable parameter sets, 3 basic frequencies.
The electrical connection is made by a quick disconnect.

95IRS1E-1CG
Infrared sensor for wavelengths from 700 to 1700 nm, suitable for coal and oil firing
2 switchable parameter sets, 3 basic frequencies.
The electrical connection is made by a 3m long, permanently connected cable.

95IRS2E-1
Infrared sensor for wavelengths from 700 to 1700 nm, suitable for coal and oil firing
4 switchable parameter sets, 21 basic frequencies.
The electrical connection is made by a quick disconnect.

95IRS2E-1CG
Infrared sensor for wavelengths from 700 to 1700 nm, suitable for coal and oil firing
4 switchable parameter sets, 21 basic frequencies.
The electrical connection is made by a 3m long, permanently connected cable.

InSight 95UV

Technical data
Flame relay (normally open contact). UV sensor, semiconductor sensor based on microprocessor, supply voltage 24V DC, process connection 1″ BSP or NPT, purge air connection 3/8″, ambient temperature range -40°C to +65°C (self-monitoring up to 80°C), 3 (S1), or 21 (S2) basic modulation frequencies, adjustable gain and ON/OFF thresholds, 4-20 mA output signal, error relay, two (S1), or four (S2) selectable parameter sets, LED display and four push buttons, quick disconnect, learning mode with the possibility of manual readjustment (S2).

95UVS1E-1
UV sensor for wavelengths from 295 to 320 nm, suitable for gas burners.
2 switchable parameter sets, 3 basic frequencies.
The electrical connection is made by a quick disconnect.

95UVS1E-1CG
UV sensor for wavelengths from 295 to 320 nm, suitable for gas burners.
2 switchable parameter sets, 3 basic frequencies.
The electrical connection is made by a 3m long, permanently connected cable.

95UVS2E-1
UV sensor for wavelengths from 295 to 320 nm, suitable for gas burners.
4 switchable parameter sets, 21 basic frequencies.
The electrical connection is made by a quick disconnect.

95UVS2E-1CG
UV sensor for wavelengths from 295 to 320 nm, suitable for gas burners.
4 switchable parameter sets, 21 basic frequencies.
The electrical connection is made via a 3m long, permanently connected cable.

InSight 95DSS

Technical data
Flame relay (normally open contact). Dual sensor (UV and IR), semiconductor sensors based on microprocessor, supply voltage 24V DC, process connection 1″ BSP or NPT, purge air connection 3/8″, ambient temperature range -40°C to +65°C (self-monitoring up to 80°C), 3 (S1), or 21 (S2) basic modulation frequencies, adjustable gain and ON/OFF thresholds, 4-20 mA output signal, error relay, two (S1) or four (S2) selectable parameter sets, LED display and four push buttons, quick release connector, learning mode with the possibility of manual readjustment (S2).

95DSS1E-1
Infrared and UV sensor, wavelength IR 700 to 1700 nm and UV 295 to 320 nm, for multi-fuel firing
2 switchable parameter sets, 3 basic frequencies.
The electrical connection is made by a quick disconnect.

95DSS1E-1CG
Infrared and UV sensor, wavelength IR 700 to 1700 nm and UV 295 to 320 nm, for multi-fuel firing
2 switchable parameter sets, 3 basic frequencies.
The electrical connection is made via a 3m long, permanently connected cable.

95DSS2E-1
Infrared and UV sensor, wavelength IR 700 to 1700 nm and UV 295 to 320 nm, for multi-fuel firing
4 switchable parameter sets, 21 basic frequencies.
The electrical connection is made by a quick disconnect.

95DSS2E-1CG
Infrared and UV sensor, wavelength IR 700 to 1700 nm and UV 295 to 320 nm, for multi-fuel firing
4 switchable parameter sets, 21 basic frequencies.
The electrical connection is made via a 3m long, permanently connected cable.

InSight 95 CEX

All InSight 95 units are also available as hazardous area units in Cenelec II 2 G EEx d II C T6 enclosures. The electrical connection is made via a permanently connected connection cable with Ex d cable gland.